With the rapid development of global computer technology and modern communication technology, people's demand for information is becoming stronger and stronger. This has led to the booming of intelligent buildings with functions of building management automation (BA, Building Automation), communication automation (CA, Communication Automation), and office automation (OA, Office Automation) worldwide. The integrated wiring system is the hardware foundation for the information exchange between the various systems in the intelligent building and between the internal system and the outside world. It not only connects voice and data communication equipment, switching equipment and other information management systems, but also makes these equipment and external Communication network connection. Building integrated wiring system (PDS) is an extension of modern "information highway" in modern buildings.

According to the requirements of the "Intelligent Building Design Standard" GB50314-2012, the integrated wiring system can be divided into office buildings, commercial buildings, cultural buildings, media buildings, sports buildings, hospital buildings, school buildings, transportation buildings, and residential buildings. Ten types of buildings, general industrial buildings, etc.

The intelligence of office buildings should meet the needs of office business information application; it should have the basic guarantee for an efficient office environment; it should meet the needs of information management for all kinds of modern office buildings. Office buildings are divided into business office buildings, administrative office buildings and financial office buildings.
The integrated wiring of office buildings should be considered as rental office buildings and self-use office buildings.

The integrated wiring of rental office buildings is generally managed by the property and invested by the developer. There are generally two approaches: one is the conventional integrated wiring approach. Set a work area according to 5-10 square meters, set the corresponding information points, and then consider the configuration of the entire system according to this amount. The other is because the users of rental office buildings are uncertain, and many users are temporarily rented out. For temporarily rented sites, regional wiring is used to complete. First lay the optical (electric) cables from the telecommunications room to the area (the area where the major customers are located), and each area is equipped with two optical fiber sockets (connected to the Ethernet switch) and two voice sockets (connected to the telephone hub or subscriber switch); The wiring of the area content is done by the customer. Of course, set the CP point (assembly point) in the routing of the horizontal cable. First, lay the horizontal cable from the telecommunication room to the CP point, and then complete the cable from the CP to the information point according to the user's own needs in the future. It is even possible to make only the main part of the cable, not the horizontal part, reserve the corresponding pipeline in advance, and wait for the user to determine the wiring according to the network construction. For rental office buildings, a comprehensive cabling form of Super Category 5 + Category 6 + Fiber Optic Hybrid can be used.

For self-use office buildings, especially office buildings of national government agencies, because their networks have intranets and extranets. There is a secret network, so integrated wiring is not a system. In addition to the demand for telephone and data, the information points must also consider the information points related to the intranet, the external network, the confidential network, and the backup. This way, the number of information points used in general projects is much larger. The installation sites, ducts, and cables of integrated wiring equipment in self-use office buildings must be physically separated. For some confidential projects, integrators often can only implement the horizontal wiring part. When the self-use office building project is implemented, the wiring network involving the confidential part will be done by an organization with security qualifications or national authorization. Self-use office buildings generally choose a relatively high level of integrated wiring (such as all categories 6 + optical fiber).

This solution is designed as a LINKBASIC lanbei category six unshielded wiring system. The system is a complete end-to-end system solution. The components of the system have undergone strict design and production, and have passed the most stringent category six component tests, links and channels. The performance exceeds the requirements of ISO/IEC11801:2008 and ANSI/TIA-568-C-2009, meets the requirements of users for safety and reliability, is suitable for different types of building integrated wiring systems, and provides customers with more reasonable system solutions.